This OEM hot surface igniter (HSI) is the direct-replacement ignition component for the ICP/Tempstar/Heil RGS120SRBB0AAA gas furnace. The igniter is energized at the start of each heat call and glows to roughly 2,000°F to ignite the burner gas. It is one of the most common furnace failure points — the brittle silicon-carbide or silicon-nitride element cracks from thermal cycling, contamination, or rough handling. When it fails, the furnace blower may run but produce no heat, the burners never light, or the control board locks out after several failed ignition attempts. This listing ships as OEM part number 1171306 (IGNITOR) and includes 1188370 (WIRING KIT IGNITER) so the harness pigtail and connector are replaced together for a clean, reliable install.

Specifications

Spec Value
Part Number 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter (HSI)
Brand ICP / Tempstar / Heil
Fits Model RGS120SRBB0AAA
Voltage 120V line-voltage HSI
Fitment OEM direct replacement

Compatibility

Engineered for the ICP Tempstar Heil RGS120SRBB0AAA gas furnace and shared across many ICP-family RGS-series single-stage gas furnaces that use this igniter platform. Always confirm your unit's igniter part number against 1171306 before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, and shut off the gas supply. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner/control access panel.
  3. Document — Photograph the igniter mounting position and wire routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and carefully withdraw the old igniter without touching the element.
  5. Install — Mount the new igniter using only the ceramic base or wiring kit pigtail — never touch the glow element with bare fingers. Reconnect per your photo.
  6. Test — Restore gas and power, call for heat, and confirm the igniter glows and the burners light within one trial.

Signs You Need a Replacement

  • Blower runs but burners never ignite and there is no heat.
  • Furnace locks out on ignition failure after 3 retry attempts.
  • Igniter shows a visible crack, blistering, or white powder on the element.
  • Resistance reads open or far out of spec on a multimeter.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120SRBB0AAA — OEM 1171306 with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120SRBB0AAA — OEM 1171306 with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120SRBB0AAA — OEM 1171306 with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.