Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS120SRBA0AAA — with Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS120SRBA0AAA — with Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part 1171306) with included igniter wiring kit (part 1188370) is the ignition source for the ICP/Heil/Tempstar RGS120SRBA0AAA gas furnace. A hot surface igniter (HSI) is a silicon-nitride or silicon-carbide element that glows orange-hot when 120V is applied during the ignition sequence, lighting the burners. It is one of the most common furnace failure points because the element is brittle and degrades with every heating cycle. Typical symptoms of a failed igniter include no heat with the blower running, a furnace that clicks but never lights, an igniter that does not glow, or a furnace that locks out after several failed ignition attempts. The included wiring kit ensures a clean, correct electrical connection during replacement.

Specifications

Spec Value
OEM Part Numbers 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Operating Voltage 120V
Brand ICP (Heil / Tempstar / Comfortmaker)
Includes Igniter + matched wiring harness kit

Compatibility

Direct-fit for the ICP RGS120SRBA0AAA and compatible ICP-family gas furnaces using this hot surface igniter and harness. Confirm the mounting bracket orientation and connector style against your existing igniter before installing.

Installation Guide

  1. Safety First — Turn off the gas and disconnect electrical power at the furnace switch, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner compartment door.
  3. Document — Photograph the igniter position and the wiring connection before removal.
  4. Remove — Unplug the igniter harness and remove the mounting screw; handle the old igniter by the ceramic base only.
  5. Install — Mount the new igniter without touching the element, then connect the new wiring kit per your photo.
  6. Test — Restore gas and power, start a heat cycle, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace blower runs but no heat is produced
  • Igniter does not glow during the ignition sequence
  • Visible cracks or breaks in the igniter element
  • Furnace locks out after repeated failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120SRBA0AAA — with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120SRBA0AAA — with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120SRBA0AAA — with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online