This OEM hot surface igniter (part #1171306) is the ignition source for the ICP Tempstar/Heil RGS120LTAB0AAA gas furnace. When the thermostat calls for heat, the control board energizes the igniter, and its silicon-carbide element glows to roughly 2,500°F to ignite the burner gas. This listing ships with the matching igniter wiring kit (part #1188370) so you have the correct pigtail and connector for a clean, code-compliant install. A failed igniter is one of the most common causes of no-heat calls — the element cracks from thermal cycling or simply burns out over time. Symptoms include the furnace clicking and trying to light but never firing, repeated lockouts, or a glow that is dim or absent.

Specifications

Spec Value
Part Number 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Element Silicon Carbide
Brand ICP / Tempstar / Heil
Voltage 120V
Application Gas Furnace
Fitment OEM

Compatibility

Engineered for the ICP Tempstar/Heil RGS120LTAB0AAA furnace and shared across many ICP-family gas furnaces using the same ignition system. Always confirm against your unit's parts breakdown before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, and shut off the gas. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner/service panel.
  3. Document — Photograph the igniter mounting and wire routing before disconnecting.
  4. Remove — Unplug the igniter connector and remove the mounting screw. Handle the old igniter by its ceramic base only.
  5. Install — Mount the new igniter without touching the carbide element, route and connect the new wiring kit per your photo.
  6. Test — Restore gas and power, then run a heat cycle and confirm the element glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace clicks and attempts ignition but never lights
  • Visible cracks or breaks in the igniter element
  • Repeated ignition lockouts or short-cycling on a call for heat
  • Element fails to glow or glows weakly

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120LTAB0AAA — Carbide Element with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120LTAB0AAA — Carbide Element with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120LTAB0AAA — Carbide Element with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online