Overview

This genuine OEM hot surface igniter (part #1171306) ignites the burners on your ICP, Tempstar, and Heil gas furnace, and this kit includes the matching igniter wiring harness (part #1188370) for a complete, plug-and-play repair. When the control board calls for heat, the igniter glows white-hot and lights the gas at the first burner. Hot surface igniters are fragile silicon-nitride or silicon-carbide elements that degrade with every heating cycle and eventually crack, leaving you with no heat, repeated ignition lockouts, or a furnace that cycles the inducer and gas valve but never lights. Including the fresh wiring kit eliminates the brittle, heat-damaged connector that is a frequent hidden cause of igniter failure.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Supply Voltage 120 VAC
Includes Igniter + Wiring Harness Kit

Compatibility

Direct OEM fit for the ICP / Tempstar / Heil model RGS120LTAA0AGAA gas furnace. The included wiring kit ensures a correct connector match for this model series.

Installation Guide

  1. Safety First – Turn off gas and power, then verify zero voltage with a multimeter.
  2. Access – Remove the burner compartment service panel.
  3. Document – Photograph the igniter mounting and harness routing before disconnecting.
  4. Remove – Unplug the igniter lead, remove the mounting screw, and lift the old igniter out without touching the element with bare hands.
  5. Install – Mount the new igniter, install the new wiring kit, and seat the connector fully.
  6. Test – Restore gas and power, call for heat, and watch for a clean glow and burner light-off.

Signs You Need a Replacement

  • No heat with the furnace locking out after several ignition attempts.
  • Visible cracks or a chalky white spot on the igniter element.
  • Igniter no longer glows when the furnace calls for heat.
  • Burnt or melted connector on the igniter wiring harness.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120LTAA0AGAA – With Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120LTAA0AGAA – With Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120LTAA0AGAA – With Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.