This is a genuine OEM hot surface igniter (part 1171306) for the ICP / Tempstar / Heil RGS120LTAA0AAA gas furnace, supplied with the matching igniter wiring kit (part 1188370). The hot surface igniter glows white-hot when the control board powers it, igniting the gas as it flows from the burners. It is one of the most failure-prone components in any modern furnace: the brittle silicon-carbide or nitride element cracks from thermal cycling, contamination, or rough handling, and a single hairline fracture stops ignition entirely. Including the wiring kit ensures the pigtail connector and leads are fresh, avoiding repeat no-heat calls caused by a worn harness.

Specifications

Spec Value
Part Number 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Includes Igniter + wiring kit
Application Gas Furnace
Fitment OEM

Compatibility

The factory-correct hot surface igniter for the ICP / Tempstar / Heil RGS120LTAA0AAA. The bundled wiring kit adapts the igniter to the original furnace harness. Confirm your existing OEM part number before ordering, as ICP used several igniter styles across model years.

Installation Guide

  1. Safety First — Shut off gas and disconnect power, then verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photo the igniter position, bracket orientation, and wire routing before disconnecting.
  4. Remove — Unplug the igniter connector and remove the mounting screw; handle the old element by its base only.
  5. Install — Mount the new igniter without touching the ceramic element, then connect it through the new wiring kit per your photo.
  6. Test — Restore gas and power, then watch a full ignition cycle to confirm a clean, on-time light.

Signs You Need a Replacement

  • Furnace clicks and tries to light but produces no heat
  • Igniter shows a visible crack or no longer glows
  • Repeated lockouts after several failed ignition attempts
  • Resistance reads open or far out of spec on a meter

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120LTAA0AAA — Furnace Ignitor Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120LTAA0AAA — Furnace Ignitor Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120LTAA0AAA — Furnace Ignitor Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.