Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS120LFBA0AGAA — With Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS120LFBA0AGAA — With Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM hot surface igniter (part number 1171306) with matching wiring kit (part number 1188370) is the direct replacement set for the ICP / Heil / Tempstar RGS120LFBA0AGAA gas furnace. The hot surface igniter glows red-hot when energized to ignite the gas at the burners during each heating cycle. Igniters are the most common furnace failure point — the brittle element cracks from thermal cycling, age, or being touched with bare fingers. A failed igniter is the usual cause of a furnace that runs the inducer and blower but never lights. The included wiring kit ensures a clean, corrosion-free connection to the control board.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Fits Model RGS120LFBA0AGAA
Fitment OEM direct replacement kit

Compatibility

Designed for the RGS120LFBA0AGAA and shared across ICP-family furnaces (Heil, Tempstar, Day & Night, Comfortmaker, Keeprite, Arcoaire) using the same igniter mount and connector. Confirm the igniter shape and connector against your existing part before installing.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment door.
  3. Document — Photograph the igniter position, bracket, and wiring routing before removal.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift the old igniter out. Handle the new element only by its base — never touch the silicon nitride tip.
  5. Install — Mount the new igniter, install the supplied wiring kit, and reconnect to the control board.
  6. Test — Restore power, start a heat call, and confirm the igniter glows and the burners light within the trial-for-ignition window.

Signs You Need a Replacement

  • Furnace runs the inducer/blower but never ignites
  • Igniter shows visible cracks or no longer glows
  • Repeated lockouts after several ignition attempts
  • Intermittent no-heat that clears on a reset

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120LFBA0AGAA — With Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120LFBA0AGAA — With Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120LFBA0AGAA — With Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online