This OEM hot surface igniter (OEM #1171306) is the ignition source for the ICP / Tempstar / Heil RGS120LEAA0AAA gas furnace. On a call for heat the control board energizes the igniter, which heats to roughly 2,000°F to light the burners. This part ships with the matching OEM wiring kit (OEM #1188370) so you get the correct harness and connector for a clean, code-correct replacement. A failed igniter is one of the most common causes of no-heat calls: the most frequent failure mode is a cracked silicon carbide element, which reads open on a multimeter and leaves the burners cold even though the rest of the sequence runs normally.

Specifications

Spec Value
Part Number 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Element Silicon Carbide
Brand ICP / Tempstar / Heil
Voltage 120V
Fits Model RGS120LEAA0AAA

Compatibility

Engineered for the ICP-family RGS120LEAA0AAA furnace and shared across Tempstar, Heil, Comfortmaker, and other ICP-built brands using this ignition platform. Always confirm against your unit's data plate before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the igniter bracket and wiring before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift the old igniter out without touching the new element with bare fingers.
  5. Install — Mount the new igniter, install the supplied wiring kit, and reconnect per your photo.
  6. Test — Restore power, run a heat cycle, and confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • Furnace blower runs but burners never light (no-heat call).
  • Igniter does not glow during the ignition sequence.
  • Visible crack, chip, or white-spotting on the element.
  • Multimeter reads open / infinite resistance across the igniter terminals.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120LEAA0AAA — 120V Silicon Carbide Ignitor with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120LEAA0AAA — 120V Silicon Carbide Ignitor with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120LEAA0AAA — 120V Silicon Carbide Ignitor with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online