Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS120LDAB0AGAA — OEM 1171306 with Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS120LDAB0AGAA — OEM 1171306 with Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM hot surface igniter (part #1171306) for the ICP/Heil/Tempstar RGS120LDAB0AGAA gas furnace, supplied with the matching igniter wiring kit (part #1188370). The hot surface igniter is the component that glows red-hot on a call for heat to ignite the gas at the burners. It operates on 120V line voltage and is one of the most common furnace failure points. When an igniter cracks or burns out, the furnace blower may run but no heat is produced, often accompanied by a furnace lockout after several failed ignition attempts.

Specifications

Spec Value
Part Number 1171306 (igniter) + 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Voltage 120V
Application Gas furnace ignition
Fitment OEM replacement

Compatibility

Engineered for the ICP family RGS120LDAB0AGAA furnace and shared platform models built by ICP for the Heil, Tempstar, Comfortmaker, and Day & Night brands. Always confirm against your unit's data plate before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner/control compartment panel.
  3. Document — Photograph the igniter bracket position and wiring before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and withdraw the old igniter. Handle the new igniter by its ceramic base only — never touch the element.
  5. Install — Mount the new igniter in the same position, then connect using the included wiring kit per your photo.
  6. Test — Restore power and run a heat cycle; confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • Furnace blower runs but produces no heat.
  • Visible crack, blistering, or break in the igniter element.
  • Furnace locks out after 3 ignition attempts (rapid status-light flashes).
  • No glow visible through the inspection port on a call for heat.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120LDAB0AGAA — OEM 1171306 with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120LDAB0AGAA — OEM 1171306 with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120LDAB0AGAA — OEM 1171306 with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online