The hot surface igniter is the component that lights the gas burners on your ICP / Tempstar / Heil RGS120LDAB0AAA furnace. When the thermostat calls for heat, the control board sends 120V to this igniter, which glows red-hot and ignites the gas stream. Because it runs through repeated heat-up and cool-down cycles, the igniter element is one of the most common furnace failures. This OEM replacement (part 1171306) ships with the matching igniter wiring kit (part 1188370) so the connector and pigtail are an exact fit — no splicing or adapters required.
Common failure symptoms include a furnace that runs the inducer and blower but never produces heat, an igniter that no longer glows, visible cracks or pitting in the silicon-carbide element, or a system that locks out after several failed ignition attempts.
| Spec | Value |
|---|---|
| Part Number | 1171306 (igniter), 1188370 (wiring kit) |
| Type | Hot Surface Igniter |
| Brand | ICP / Tempstar / Heil |
| Voltage | 120V |
| Fits Model | RGS120LDAB0AAA |
| Fitment | OEM Direct Replacement |
Engineered for the ICP Tempstar Heil RGS120LDAB0AAA gas furnace and shared platform models that use the 1171306 igniter. Always confirm against your unit's model and serial plate before installing.