Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS120LDAB0AAA — Furnace Ignition Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS120LDAB0AAA — Furnace Ignition Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

The hot surface igniter is the component that lights the gas burners on your ICP / Tempstar / Heil RGS120LDAB0AAA furnace. When the thermostat calls for heat, the control board sends 120V to this igniter, which glows red-hot and ignites the gas stream. Because it runs through repeated heat-up and cool-down cycles, the igniter element is one of the most common furnace failures. This OEM replacement (part 1171306) ships with the matching igniter wiring kit (part 1188370) so the connector and pigtail are an exact fit — no splicing or adapters required.

Common failure symptoms include a furnace that runs the inducer and blower but never produces heat, an igniter that no longer glows, visible cracks or pitting in the silicon-carbide element, or a system that locks out after several failed ignition attempts.

Specifications

Spec Value
Part Number 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Voltage 120V
Fits Model RGS120LDAB0AAA
Fitment OEM Direct Replacement

Compatibility

Engineered for the ICP Tempstar Heil RGS120LDAB0AAA gas furnace and shared platform models that use the 1171306 igniter. Always confirm against your unit's model and serial plate before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter and shut off the gas.
  2. Access — Remove the burner/service panel.
  3. Document — Photograph the igniter bracket and wiring before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and lift out the old igniter. Handle only by the ceramic base — never touch the element.
  5. Install — Mount the new igniter, route and connect the supplied wiring kit per your photo.
  6. Test — Restore gas and power, run a heat cycle, and confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • Igniter does not glow on a call for heat
  • Furnace locks out after repeated ignition attempts
  • Visible cracks, breaks, or white spots on the element
  • No heat despite the inducer and blower running

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120LDAB0AAA — Furnace Ignition Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120LDAB0AAA — Furnace Ignition Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120LDAB0AAA — Furnace Ignition Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online