Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS120HTBA0AAA — Silicon Nitride with Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS120HTBA0AAA — Silicon Nitride with Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part #1171306) is the ignition component for the ICP/Heil/Tempstar RGS120HTBA0AAA 120,000 BTU gas furnace. When the furnace calls for heat, the control board energizes this igniter; it glows to roughly 2,000°F to light the burner gas. This listing includes the matching igniter wiring kit (#1188370) for a complete, plug-and-play replacement. A failed igniter is one of the most common no-heat causes — the element becomes brittle and cracks over years of heating cycles, leaving the furnace unable to light.

Specifications

Spec Value
Part Number 1171306 (+ 1188370 wiring kit)
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Element Silicon Nitride
Voltage 120V
Application Gas Furnace

Compatibility

Direct fit for the ICP RGS120HTBA0AAA gas furnace and shared-platform Heil, Tempstar, Comfortmaker, and Arcoaire models using the same ignition assembly. Always verify your OEM part number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch/breaker and shut off the gas. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner/service panel.
  3. Document — Photograph the igniter bracket and wiring before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift the old igniter out without touching the element with bare hands.
  5. Install — Mount the new igniter, attach the included wiring kit, and reconnect per your photo.
  6. Test — Restore gas and power, then run a heat cycle and confirm the igniter glows and the burner lights.

Signs You Need a Replacement

  • Furnace blower runs but there is no flame or heat
  • Igniter does not glow during the ignition sequence
  • Visible cracks or fractures in the igniter element
  • Furnace locks out after several failed ignition attempts

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120HTBA0AAA — Silicon Nitride with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120HTBA0AAA — Silicon Nitride with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120HTBA0AAA — Silicon Nitride with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online