Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS120HSBB0AAA — OEM 1171306 with Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS120HSBB0AAA — OEM 1171306 with Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the OEM hot surface igniter for the ICP / Tempstar / Heil RGS120HSBB0AAA gas furnace, supplied as factory part number 1171306 (IGNITOR) and paired with wiring kit 1188370 (WIRING KIT IGNITER). The igniter is the component that glows red-hot at the start of every heat cycle to light the burners. When it fails, the furnace draft inducer and gas valve may sequence normally but the burners never light, leaving you with cold air or a unit that locks out after several ignition attempts. Hot surface igniters are a normal wear item — the silicon carbide or nitride element becomes brittle with thousands of heating cycles and eventually cracks. Replacing the igniter at the first sign of weak or intermittent ignition restores reliable, fast burner lighting.

Specifications

Spec Value
Part Number 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Fits Model RGS120HSBB0AAA
Application Gas furnace burner ignition
Fitment OEM direct replacement

Compatibility

Engineered as a direct OEM fit for the ICP / Tempstar / Heil RGS120HSBB0AAA gas furnace. The included wiring kit ensures a clean electrical connection to the furnace control board. Always confirm your model and serial tag before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter, and shut off the gas supply.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter mounting and wire routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift out the old igniter without touching the element.
  5. Install — Mount the new igniter, handling it only by the ceramic base, and connect using the supplied wiring kit per your photo.
  6. Test — Restore gas and power, then run a heat cycle and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace clicks and runs the inducer but burners never light
  • Igniter glows weakly, unevenly, or not at all
  • Repeated ignition lockouts after 3-4 trial cycles
  • Visible cracks or a broken element on the old igniter

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120HSBB0AAA — OEM 1171306 with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120HSBB0AAA — OEM 1171306 with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120HSBB0AAA — OEM 1171306 with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online