Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS120HRCA0AAA — 120V Nitride Ignitor + Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS120HRCA0AAA — 120V Nitride Ignitor + Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part 1171306) is the ignition component for the ICP / Tempstar / Heil RGS120HRCA0AAA gas furnace, supplied here with its matching wiring kit (part 1188370). On a call for heat, the furnace control board sends 120V to the igniter, which glows red-hot and ignites the gas at the burners. When an igniter ages, the silicon nitride element develops micro-cracks and hairline fractures that increase resistance until it can no longer reach ignition temperature. Typical failure symptoms are a furnace that clicks and tries to light but never fires, a glowing igniter that produces no flame, repeated lockouts after 2–3 ignition attempts, or no glow at all. Replacing a weak igniter is one of the most common no-heat repairs on this furnace platform.

Specifications

Spec Value
Part Number 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Voltage 120V
Element Silicon nitride
Includes Igniter + wiring kit
Fitment RGS120HRCA0AAA

Compatibility

Direct fit for the ICP, Tempstar, Heil, Comfortmaker, and Arcoaire RGS120HRCA0AAA gas furnace and related RGS-series models that use this ignition assembly. Always confirm the OEM part number stamped on your existing igniter before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter and shut off the gas.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the igniter mounting and wiring routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift the old igniter out without touching the new element with bare fingers.
  5. Install — Mount the new igniter in the same position, connect the supplied wiring kit, and confirm the element sits properly over the burner.
  6. Test — Restore gas and power, then run a heat cycle and verify a clean glow, ignition, and stable flame.

Signs You Need a Replacement

  • Furnace clicks and attempts ignition but never lights
  • Igniter glows but the burners do not fire
  • System locks out after several failed ignition attempts
  • No glow at all when calling for heat

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120HRCA0AAA — 120V Nitride Ignitor + Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120HRCA0AAA — 120V Nitride Ignitor + Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120HRCA0AAA — 120V Nitride Ignitor + Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online