Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS120HFAA0AGAA — Direct-Fit OEM Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS120HFAA0AGAA — Direct-Fit OEM Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter is the direct-fit ignition source for the ICP / Tempstar / Heil RGS120HFAA0AGAA gas furnace. When a heat call is received, the control board energizes the igniter, which glows red-hot to ignite the gas at the burners. This kit includes igniter OEM #1171306 and the matching igniter wiring kit OEM #1188370, so you replace both the heating element and its harness in one job. Hot surface igniters are the single most common failure point in modern gas furnaces — the silicon nitride element becomes brittle with each heating cycle and eventually cracks, leaving you with a furnace that clicks but never lights.

Specifications

Spec Value
Part Number 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Fits Model RGS120HFAA0AGAA
Includes Igniter element + igniter wiring kit
Fitment OEM direct replacement

Compatibility

Engineered as the factory ignition assembly for the ICP/Tempstar/Heil RGS120HFAA0AGAA furnace and shared across the RGS120 gas furnace family. Because this is an OEM part with the matching wiring harness, fitment, glow time, and amp draw match factory spec exactly — no universal-igniter guesswork.

Installation Guide

  1. Safety First — Switch off the furnace at the disconnect and shut the gas. Verify zero voltage at the igniter terminals with a multimeter.
  2. Access — Remove the furnace blower-compartment service panel.
  3. Document — Photograph the igniter mounting and wiring routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the igniter mounting screw, and carefully withdraw the brittle element from the burner assembly without touching the glow surface.
  5. Install — Mount the new igniter, handling it only by the ceramic base, and connect the new wiring kit per your photo.
  6. Test — Restore gas and power, then run a heat cycle and confirm the igniter glows and the burners light within seconds.

Signs You Need a Replacement

  • Furnace ignition sequence runs but burners never light (no glow).
  • Visible crack, chip, or white spot on the igniter element.
  • Repeated lockouts after several failed ignition attempts.
  • Open-circuit / infinite resistance reading across the igniter.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120HFAA0AGAA — Direct-Fit OEM Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120HFAA0AGAA — Direct-Fit OEM Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120HFAA0AGAA — Direct-Fit OEM Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online