Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS120HEAA0AKAA — Includes Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS120HEAA0AKAA — Includes Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part number 1171306) ignites the burners on the ICP / Tempstar / Heil RGS120HEAA0AKAA gas furnace, and ships with the matching igniter wiring kit (part number 1188370) for a clean, complete installation. On a heat call, the control board sends line voltage to the igniter, which glows white-hot to ignite the gas at the burners. Hot surface igniters are brittle and degrade with every heating cycle; eventually the silicon nitride or carbide element cracks, opens, or simply fails to reach ignition temperature, leaving you with no heat. Replacing the igniter — and the often-corroded wiring harness with it — restores dependable single-try ignition.

Specifications

Spec Value
Part Number 1171306 (igniter) + 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Operating Voltage 120V
Kit Contents Igniter + igniter wiring harness
Fitment OEM Direct Replacement

Compatibility

Direct replacement for the ICP RGS120HEAA0AKAA furnace and related ICP, Tempstar, Heil, and Comfortmaker models that call out the 1171306 igniter. The included 1188370 harness ensures a correct plug-and-play connection to the furnace control board.

Installation Guide

  1. Safety First — Shut off gas and power, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment access panel.
  3. Document — Photograph the igniter mounting and harness routing.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift out the old igniter. Never touch the new element with bare fingers — oils shorten its life.
  5. Install — Mount the new igniter, route and connect the new wiring kit per your photo.
  6. Test — Restore gas and power and confirm the igniter glows and lights the burners on the first try.

Signs You Need a Replacement

  • No heat with no visible glow from the igniter on a heat call
  • Visible cracks, breaks, or white flaking on the igniter element
  • Furnace locks out after several failed ignition attempts
  • Intermittent ignition or delayed light-off with a rollout of gas smell

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120HEAA0AKAA — Includes Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120HEAA0AKAA — Includes Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120HEAA0AKAA — Includes Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online