Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS120HDBA0AAA Gas Furnace with Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS120HDBA0AAA Gas Furnace with Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part #1171306) is the ignition source for the ICP / Tempstar / Heil RGS120HDBA0AAA gas furnace. On every call for heat the furnace control board energizes the igniter, which glows to roughly 2,000°F and lights the gas at the burners. Because the igniter cycles on with every heating call, its silicon-nitride/silicon-carbide element is one of the most common wear items in a gas furnace. A cracked, eroded, or open igniter is the leading cause of "no heat" and short-cycle lockout faults. This listing includes the matching OEM igniter wiring kit (part #1188370) so the harness and connector are replaced together, eliminating the brittle, heat-baked leads that often fail alongside the element.

Specifications

Spec Value
Part Number 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Voltage 120 VAC
Application Gas Furnace Ignition
Fits Model RGS120HDBA0AAA

Compatibility

Engineered for the ICP family RGS120HDBA0AAA gas furnace and shared across many ICP, Tempstar, Heil, Comfortmaker, and Arcoaire RGS-series furnaces using the same ignition system. Verify your existing igniter part number before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect power at the furnace switch; verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter leads and mounting position before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and lift the old igniter out without touching the element.
  5. Install — Mount the new igniter, install the supplied wiring kit, and reconnect per your photo. Handle the element by the ceramic base only.
  6. Test — Restore gas and power, then run a heat cycle and confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • Furnace blows cold air or fails to ignite on a call for heat.
  • Igniter does not glow, or glows weakly/unevenly.
  • Visible cracks, chips, or white hot-spots on the element.
  • Repeated ignition-failure lockouts (3-strike fault) on the control board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120HDBA0AAA Gas Furnace with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120HDBA0AAA Gas Furnace with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120HDBA0AAA Gas Furnace with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online