Overview

This is the genuine OEM hot surface igniter (part number 1171306), supplied with its matching igniter wiring kit (part number 1188370), for the ICP / Heil / Tempstar RGS120HDAA0AGAA gas furnace. The hot surface igniter is an electrically heated element that glows incandescent during the ignition sequence to light the burner gas — replacing older standing-pilot designs. On each heat call, the control board energizes the igniter, it reaches ignition temperature in a few seconds, the gas valve opens, and the burners light. The included wiring kit provides the correct OEM connector and harness leads so the igniter mates cleanly to the furnace harness without splicing. Hot surface igniters are a wear item: the brittle element cracks from thermal cycling, handling, or repeated short-cycling, which is one of the most frequent causes of no-heat calls.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar (OEM)
Function Burner ignition
Includes Igniter + OEM wiring harness kit
Fitment RGS120HDAA0AGAA

Compatibility

Direct-fit for the RGS120HDAA0AGAA and compatible across ICP-built Heil, Tempstar, and Comfortmaker gas furnaces specifying this igniter and harness. Handle the element only by its ceramic base — never touch the silicon nitride/carbide tip. Confirm fitment against your unit's parts list before installing.

Installation Guide

  1. Safety First — Shut off gas and disconnect power. Verify zero voltage at the control board with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter bracket position and harness routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and lift out the old igniter without touching its tip.
  5. Install — Fit the new igniter and the supplied wiring kit, secure the bracket, and seat the connector fully.
  6. Test — Restore gas and power, run a heat call, and confirm the igniter glows and the burners light within the normal trial-for-ignition time.

Signs You Need a Replacement

  • No glow during the ignition sequence
  • Furnace ignition lockout / repeated retry codes
  • Visible crack or break in the igniter element
  • Intermittent or delayed burner ignition

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120HDAA0AGAA — Includes Igniter Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120HDAA0AGAA — Includes Igniter Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120HDAA0AGAA — Includes Igniter Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.