Overview

This OEM hot surface igniter kit for the ICP / Tempstar / Heil RGS102LFBB0AAA includes the igniter element (part number 1171306) and the matching igniter wiring kit (part number 1188370). On a call for heat, the furnace control sends voltage to the igniter, which glows red-hot and ignites the gas at the burners. Hot surface igniters are brittle and degrade with every heating cycle — the silicon nitride or carbide element thins, cracks, and eventually fails open. The result is a furnace that runs its ignition sequence but never lights, often locking out after several tries. Replacing the igniter with the OEM element and a fresh wiring harness restores dependable first-try ignition.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil)
Includes Igniter element + wiring harness kit
Fitment OEM — RGS102LFBB0AAA
Application Gas furnace ignition

Compatibility

A direct OEM fit for the RGS102LFBB0AAA and shared ICP-family furnaces sold under the Tempstar, Heil, and Comfortmaker brands that use this hot surface igniter. Confirm the igniter mounting and connector against your existing part before installing.

Installation Guide

  1. Safety First — Disconnect electrical power and verify zero voltage with a multimeter. Shut off gas while servicing.
  2. Access — Remove the furnace front panel to reach the burner assembly and igniter.
  3. Document — Photograph the igniter position and harness routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and lift out the old element. Handle by the ceramic base only — never touch the igniter surface.
  5. Install — Mount the new igniter, install the new wiring kit, and seat the connector fully. Keep fingers off the hot surface element.
  6. Test — Restore gas and power, call for heat, and confirm the igniter glows and lights the burners on the first cycle.

Signs You Need a Replacement

  • Furnace clicks through ignition but burners never light
  • Igniter no longer glows, or glows weak/uneven
  • Visible cracks, chips, or white-spotting on the element
  • Furnace locks out after multiple failed ignition attempts

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS102LFBB0AAA — OEM 1171306 with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS102LFBB0AAA — OEM 1171306 with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS102LFBB0AAA — OEM 1171306 with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online