Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS102LEAB0AAA — Direct-Fit OEM Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS102LEAB0AAA — Direct-Fit OEM Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM hot surface igniter assembly for the ICP / Heil / Tempstar RGS102LEAB0AAA gas furnace. The kit includes igniter part number 1171306 and the matching igniter wiring kit 1188370 for a complete, direct-fit replacement. The hot surface igniter (HSI) is energized at the start of each heat call; it glows red-hot and ignites the gas as it flows across the burners. A failed igniter is one of the most common causes of no-heat conditions. Typical failure symptoms include the furnace cycling on the inducer and gas valve but never lighting, a cracked or visibly damaged igniter element, or a unit that locks out after several failed ignition attempts.

Specifications

Spec Value
Part Number 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter (HSI)
Brand ICP / Heil / Tempstar
Application Gas Furnace Ignition
Fit OEM Direct Replacement

Compatibility

Engineered for the ICP/Heil/Tempstar RGS102LEAB0AAA furnace and shared platform models from Comfortmaker and other International Comfort Products brands using the same burner and ignition assembly. Always confirm your OEM part number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and shut off the gas supply. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner compartment service panel.
  3. Document — Photograph the igniter mounting and wiring routing before disconnecting.
  4. Remove — Unplug the igniter wiring connector, remove the mounting screw, and carefully lift out the old igniter without touching the element.
  5. Install — Mount the new igniter with the supplied hardware, install the new wiring kit, and reconnect per your photo. Handle the silicon-carbide element by the ceramic base only.
  6. Test — Restore gas and power, then start a heat cycle and confirm the igniter glows and lights the burners reliably.

Signs You Need a Replacement

  • Furnace runs the inducer and clicks the gas valve but never ignites.
  • Visible cracks, chips, or breaks in the igniter element.
  • System locks out after 3–4 failed ignition tries.
  • No glow visible from the igniter during a heat call.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS102LEAB0AAA — Direct-Fit OEM Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS102LEAB0AAA — Direct-Fit OEM Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS102LEAB0AAA — Direct-Fit OEM Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online