Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS102HTBB0AAA — Furnace Ignitor Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS102HTBB0AAA — Furnace Ignitor Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (HSI) is the direct-fit ignition component for the ICP / Tempstar / Heil RGS102HTBB0AAA gas furnace. The igniter glows orange-hot on each call for heat to ignite the gas at the burner. It is supplied with the matching wiring kit (OEM 1188370) so the harness and connector match the original assembly exactly. A cracked, eroded, or open igniter is one of the most common no-heat failures on this furnace platform — the control board calls for ignition, but the burners never light.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter (HSI)
Brand ICP / Tempstar / Heil
Voltage 120V
Application Gas Furnace Ignition
Fitment OEM Direct Replacement

Compatibility

Engineered as the factory replacement for the ICP / Tempstar / Heil model RGS102HTBB0AAA. Shared across many Comfortmaker, Heil, and Tempstar furnaces built on the same chassis. Always confirm your existing igniter part number before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect power at the furnace switch and breaker. Verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter bracket and the wiring harness routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and carefully withdraw the old igniter — never touch the ceramic element with bare fingers.
  5. Install — Seat the new igniter so the element sits in the burner flame path, fasten the screw, and connect the new wiring kit.
  6. Test — Restore gas and power, then run a heat cycle and confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • Furnace fails to ignite — blower runs but no heat
  • Igniter does not glow during the ignition sequence
  • Visible cracks, chips, or white-spotting on the ceramic element
  • Repeated lockouts / flashing control-board fault codes

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS102HTBB0AAA — Furnace Ignitor Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS102HTBB0AAA — Furnace Ignitor Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS102HTBB0AAA — Furnace Ignitor Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online