Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS102HFCB0AAA — with Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS102HFCB0AAA — with Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part number 1171306), supplied with the matching igniter wiring kit (part number 1188370), is the ignition source for the ICP/Heil/Tempstar RGS102HFCB0AAA gas furnace. On each call for heat the control board sends 120 volts to the igniter, which glows red-hot and lights the gas at the burners. Hot surface igniters are a wear item: the silicon-nitride or silicon-carbide element becomes brittle over thousands of heating cycles and eventually cracks or fails to reach ignition temperature. A failed igniter is the single most common reason a furnace blows cold air or locks out after several ignition attempts. The included wiring kit ensures a clean, correct electrical connection during replacement.

Specifications

Spec Value
OEM Part Number 1171306 (igniter)
Included Wiring Kit 1188370
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Operating Voltage 120 VAC
Fits Model RGS102HFCB0AAA

Compatibility

Direct OEM replacement for the ICP/Heil/Tempstar RGS102HFCB0AAA and other furnaces that call out part number 1171306. The element is fragile — never touch the igniter surface with bare fingers, as skin oils shorten its life.

Installation Guide

  1. Safety First — Shut off gas and disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter bracket and wire routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift out the old igniter without bending the bracket.
  5. Install — Mount the new igniter (handle only the ceramic base), secure the screw, and connect the supplied wiring kit.
  6. Test — Restore gas and power, call for heat, and confirm the igniter glows and lights the burners.

Signs You Need a Replacement

  • Furnace blows cold air or never lights the burners.
  • Control board locks out after 3 ignition attempts.
  • Igniter shows visible cracks or no longer glows.
  • Resistance reads open (infinite) on a multimeter.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS102HFCB0AAA — with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS102HFCB0AAA — with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS102HFCB0AAA — with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online