Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS101SFAB0AAAA — OEM 1171306 with Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS101SFAB0AAAA — OEM 1171306 with Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part #1171306) is the ignition component for the ICP Tempstar Heil RGS101SFAB0AAAA gas furnace, and ships with the matching igniter wiring kit (#1188370) for a complete, plug-ready replacement. The igniter is a 120V silicon-carbide/silicon-nitride element that glows red-hot on a call for heat to ignite the gas at the burner. It is one of the most common furnace failure points: the element is brittle and degrades with every heating cycle. Typical failure symptoms are no ignition, the furnace running the inducer and gas valve but never lighting, repeated lockouts after three or four trial cycles, and a visibly cracked or non-glowing element.

Specifications

Spec Value
Part Number 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil)
Voltage 120V
Fits Model RGS101SFAB0AAAA
Includes Igniter + igniter wiring harness kit

Compatibility

Engineered for the ICP Tempstar Heil RGS101SFAB0AAAA furnace and shared platform models across the ICP family (Tempstar, Heil, Comfortmaker). Always confirm against your unit's model and serial tag before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter mounting and wiring before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and lift the old element out without touching the new element's surface (skin oils shorten its life).
  5. Install — Mount the new igniter, install the supplied wiring kit, and reconnect per your photo.
  6. Test — Restore power and watch a full ignition cycle to confirm the element glows and the burners light.

Signs You Need a Replacement

  • Furnace runs inducer and gas valve but never ignites
  • Element no longer glows or glows weak/uneven
  • Visible cracks or breaks in the igniter element
  • Repeated ignition lockouts after several trial-for-ignition cycles

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS101SFAB0AAAA — OEM 1171306 with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS101SFAB0AAAA — OEM 1171306 with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS101SFAB0AAAA — OEM 1171306 with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera