Overview

This is a genuine OEM hot surface igniter (part #1171306) bundled with the matching igniter wiring kit (part #1188370) for the ICP / Heil / Tempstar RGS101LRCB0AAA gas furnace. The hot surface igniter glows red-hot at the start of each heating cycle to ignite gas at the burners. Over time the element develops hairline cracks or weakens until it can no longer reach ignition temperature, leaving the furnace unable to fire and locking out after repeated failed trials. Common symptoms include no heat, the inducer running with no burner ignition, or an igniter that no longer glows. Installing a new igniter together with fresh wiring restores dependable startup.

Specifications

Spec Value
Part Number 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Fitment OEM
Application Gas Furnace Ignition

Compatibility

Directly fits the ICP RGS101LRCB0AAA furnace and shares the ignition platform used across many Heil, Tempstar, and Comfortmaker models of the same series. Confirm your model and serial before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, shut off the gas, and verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/blower compartment service panel.
  3. Document — Photograph the igniter mounting position and wiring routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and withdraw the old igniter without touching the new element with bare fingers.
  5. Install — Mount the new igniter, route and connect the new wiring kit per your photo, and verify burner-relative position.
  6. Test — Restore gas and power, run a heat cycle, and confirm the igniter glows and the burners light cleanly.

Signs You Need a Replacement

  • Furnace runs the inducer but never ignites
  • Igniter no longer glows or glows weakly
  • Visible cracks or white blistering on the element
  • Repeated ignition lockouts or short-cycling on a call for heat

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS101LRCB0AAA — Includes Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS101LRCB0AAA — Includes Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS101LRCB0AAA — Includes Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.