Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS101LRAA0AAAA — With Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS101LRAA0AAAA — With Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM hot surface igniter (PN 1171306) bundled with the matching igniter wiring kit (PN 1188370) for the ICP / Tempstar / Heil RGS101LRAA0AAAA gas furnace. The hot surface igniter is the component that glows red-hot at the start of each heat cycle to light the burners. On a call for heat, the control board sends line voltage to the igniter; once it reaches ignition temperature the gas valve opens and the burners light. Igniters are brittle and consumable — they crack from thermal cycling, contamination, or rough handling — and a failed igniter is the single most common cause of a furnace that runs the inducer and blower but never produces heat. The included wiring kit ensures a clean, correct connection to the furnace harness.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Application Gas Furnace Burner Ignition
Fit OEM Replacement

Compatibility

Designed for the ICP RGS101LRAA0AAAA and compatible ICP-family gas furnaces marketed under the Tempstar, Heil, Comfortmaker, and Arcoaire names. Verify your furnace uses a hot surface ignition system before ordering.

Installation Guide

  1. Safety First — Switch off the furnace at the disconnect and gas shutoff, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter bracket position and wiring before disconnecting.
  4. Remove — Unplug the igniter connector and remove the mounting screw; handle the old igniter only by its ceramic base.
  5. Install — Mount the new igniter without touching the silicon-carbide element, then connect it using the supplied wiring kit per your photo.
  6. Test — Restore power and gas, call for heat, and confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • Furnace inducer and blower run but no heat is produced
  • Visible crack or break in the igniter element
  • Igniter does not glow on a call for heat
  • Repeated ignition lockouts or short cycling

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS101LRAA0AAAA — With Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS101LRAA0AAAA — With Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS101LRAA0AAAA — With Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online