This OEM hot surface igniter (HSI) assembly is the direct ignition component for the ICP / Heil / Tempstar RGS101LFCA0AAA gas furnace. The igniter (OEM part 1171306) glows red-hot when energized by the control board, lighting the burner gas on each heating call. This listing ships with the matching igniter wiring kit (OEM 1188370) so the connector pigtail and harness are replaced together, eliminating the brittle, heat-fatigued wiring that commonly fails alongside the igniter element itself. Hot surface igniters are a wear item — the silicon nitride/carbide element degrades with every heat cycle and eventually cracks or fails open. Typical failure symptoms include no ignition, a furnace that clicks and tries to light but never fires, a visible crack in the igniter element, or a unit that locks out after several failed trials for ignition.

Specifications

Spec Value
Part Number 1171306 (Igniter) + 1188370 (Wiring Kit)
Type Hot Surface Igniter (HSI)
Brand ICP / Heil / Tempstar / Comfortmaker
Application Gas Furnace Ignition
Fit OEM Replacement
Model RGS101LFCA0AAA

Compatibility

Direct-fit replacement for the ICP/Heil/Tempstar/Comfortmaker RGS101LFCA0AAA furnace and other RGS-series models that call out OEM igniter 1171306. Always confirm the original igniter part number stamped on your existing component or listed in your model's parts breakdown before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch/breaker and shut off the gas supply. Verify zero voltage with a multimeter before touching any wiring.
  2. Access — Remove the furnace front/burner service panel.
  3. Document — Photograph the igniter mounting and wire routing before disconnecting anything.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and lift the old igniter out of the burner assembly. Handle only by the ceramic base — never touch the fragile element.
  5. Install — Seat the new igniter so the element sits correctly in the burner flame path, secure the mounting screw, and connect the new wiring kit harness/connector.
  6. Test — Restore gas and power, then run a heat cycle and confirm the igniter glows and the burners light cleanly.

Signs You Need a Replacement

  • Furnace attempts to light but never ignites the burners.
  • Visible crack, chip, or white/gray spot on the igniter element.
  • Igniter does not glow when the heating cycle starts.
  • Furnace locks out after repeated failed ignition trials.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS101LFCA0AAA — OEM 1171306 with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS101LFCA0AAA — OEM 1171306 with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS101LFCA0AAA — OEM 1171306 with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.