Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS101LFAA0AAAA — Includes Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS101LFAA0AAAA — Includes Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM hot surface igniter (part number 1171306) ships with the matching igniter wiring kit (part number 1188370) for the ICP/Heil/Tempstar RGS101LFAA0AAAA gas furnace. The igniter glows red-hot when energized to light the burners at the start of each heat cycle. Hot surface igniters are brittle and degrade over thousands of cycles; they crack, develop hairline fractures, or simply burn out. The included wiring kit replaces the harness and connector, eliminating intermittent no-light faults caused by corroded or loose terminals. Symptoms of a failed igniter include no heat, a furnace that locks out after several ignition attempts, or a glowing igniter that never lights the burners.

Specifications

Spec Value
Part Number 1171306 (igniter)
Included Kit 1188370 (igniter wiring kit)
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Function Burner ignition
Fits Model RGS101LFAA0AAAA

Compatibility

Direct OEM fit for the ICP RGS101LFAA0AAAA and shared ICP/Heil/Tempstar/Comfortmaker furnaces using igniter 1171306 with wiring kit 1188370. Confirm your existing igniter and connector style before installing.

Installation Guide

  1. Safety First — Disconnect electrical power and verify zero voltage with a multimeter. Allow the igniter to cool fully.
  2. Access — Remove the burner/service panel.
  3. Document — Photograph the igniter position and wiring routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and carefully withdraw the old igniter without touching the ceramic element.
  5. Install — Mount the new igniter handling it only by the ceramic base, install the new wiring kit harness, and route it clear of hot surfaces.
  6. Test — Restore power, start a heat call, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • No heat and the furnace locks out after multiple ignition attempts
  • Igniter glows but burners fail to light
  • Visible cracks or breaks in the ceramic element
  • No glow at all during a heat call

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS101LFAA0AAAA — Includes Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS101LFAA0AAAA — Includes Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS101LFAA0AAAA — Includes Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online