Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS101LEAB0AAAA — 120V with Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS101LEAB0AAAA — 120V with Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM hot surface igniter (part #1171306) for the ICP / Heil / Tempstar RGS101LEAB0AAAA gas furnace, supplied with its matching igniter wiring kit (part #1188370). The hot surface igniter glows red-hot on each call for heat to light the gas at the burners and operates on 120V. It is the most common failure point in a modern furnace's ignition sequence: when it cracks or weakens, the furnace runs its inducer and blower but produces no heat, or it short-cycles into an ignition lockout. Replacing the igniter together with its wiring kit restores fast, reliable lighting.

Specifications

Spec Value
OEM Part Numbers 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Voltage 120V
Application Gas Furnace Ignition
Fitment OEM Direct Replacement

Compatibility

Direct-fit replacement for the ICP-family RGS101LEAB0AAAA gas furnace and the shared Heil, Tempstar, and Comfortmaker chassis. Confirm the OEM number stamped on your existing igniter before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect power at the furnace switch; verify zero voltage with a multimeter.
  2. Access — Remove the furnace blower-compartment and burner service panels.
  3. Document — Photograph the igniter mounting and wiring harness routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and lift the old igniter out — handle by the ceramic base only, never the element.
  5. Install — Seat the new igniter in the burner flame path, secure the screw, and connect the new wiring kit.
  6. Test — Restore gas and power and watch a full cycle: the igniter should glow bright orange and light the burners within seconds.

Signs You Need a Replacement

  • Furnace runs but produces no heat (no ignition)
  • Visible crack, blistering, or white spots on the element
  • Repeated ignition lockouts or short-cycling on call for heat
  • Igniter glows weakly or not at all during ignition

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS101LEAB0AAAA — 120V with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS101LEAB0AAAA — 120V with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS101LEAB0AAAA — 120V with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online