Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS101HTAA0AAAA — 120V OEM Ignition Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS101HTAA0AAAA — 120V OEM Ignition Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part #1171306) is the ignition component for the ICP/Heil/Tempstar RGS101HTAA0AAAA gas furnace, supplied with the matching igniter wiring kit (#1188370). The igniter is energized by the control board at the start of each heating cycle, glowing to roughly 2,000°F to light the gas burners. A failed igniter is the single most common reason a furnace stops producing heat: it will crack, develop hot spots, or open completely after thousands of heating cycles. Symptoms include no ignition, a furnace that clicks and the inducer runs but no flame appears, or a unit that lockouts after several failed ignition attempts. The included wiring kit ensures a clean, OEM-spec electrical connection.

Specifications

Spec Value
Part Number 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Voltage 120V
Fitment OEM

Compatibility

Engineered for the ICP family RGS101HTAA0AAAA furnace and shared platform models across the Heil, Tempstar, and Comfortmaker brands. Always verify against your unit's part list before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter mounting and wiring before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and carefully lift the old igniter out — handle only by the ceramic base, never the fragile element.
  5. Install — Seat the new igniter, secure the screw, and connect using the included wiring kit per your photo.
  6. Test — Restore power and run a heat cycle; confirm the igniter glows and burners light within seconds.

Signs You Need a Replacement

  • No heat — inducer and gas valve cycle but burners never light
  • Visible cracks, blisters, or white/grey spots on the igniter element
  • Furnace locks out after 3 failed ignition attempts
  • Igniter does not glow when energized at the start of the cycle

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS101HTAA0AAAA — 120V OEM Ignition Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS101HTAA0AAAA — 120V OEM Ignition Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS101HTAA0AAAA — 120V OEM Ignition Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online