OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This OEM hot surface igniter (part #1171306) is the ignition component for the ICP/Heil/Tempstar RGS101HSCB0AAA gas furnace, supplied with the matching igniter wiring kit (#1188370). At the start of each heat call the control board energizes the igniter, which glows to roughly 2,000°F to light the gas burners. The igniter is the most frequently replaced furnace part because it crack, develops hot spots, or opens electrically after thousands of cycles. Common symptoms are no heat with the inducer running, burners that fail to light, or a furnace that lockouts after several attempts. The included wiring kit provides a clean OEM-spec electrical connection for a reliable repair.
| Spec | Value |
|---|---|
| Part Numbers | 1171306 (igniter), 1188370 (wiring kit) |
| Type | Hot Surface Igniter |
| Brand | ICP / Heil / Tempstar |
| Voltage | 120V |
| Fitment | OEM |
Engineered for the ICP family RGS101HSCB0AAA furnace and shared-platform models across the Heil, Tempstar, and Comfortmaker brands. Verify against your unit's part list before ordering.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.