Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS101HRCB0AAA — OEM 1171306 | Ships Today
ICP

ICP Hot Surface Igniter for RGS101HRCB0AAA — OEM 1171306 | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (HSI) is the original ignition component for the ICP / Heil / Tempstar RGS101HRCB0AAA gas furnace. The igniter is energized at the start of each heating call, glowing red-hot to ignite the gas flowing from the burner manifold. It is one of the most common wear parts in a furnace because it cycles every time the unit fires and operates at extreme temperature. This listing covers OEM igniter 1171306 along with the matching igniter wiring kit (1188370), so you receive the correct connector and harness for a clean, factory-style replacement.

Specifications

Spec Value
Part Number 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Fits Model RGS101HRCB0AAA
Fitment OEM Direct Replacement

Compatibility

Designed as the direct factory replacement for the RGS101HRCB0AAA furnace and the family of ICP-built RGS gas furnaces sold under the Heil, Tempstar, and Comfortmaker brands. Always confirm your model and serial tag before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and verify zero voltage with a multimeter. Shut off the gas supply.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter bracket position and wiring before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift out the old igniter without touching the silicon-carbide element.
  5. Install — Mount the new igniter, install the wiring kit connector, and reconnect per your photo. Handle by the ceramic base only.
  6. Test — Restore gas and power, then watch a full ignition cycle to confirm a clean light-off.

Signs You Need a Replacement

  • Furnace clicks and the inducer runs, but there is no glow and no flame
  • Visible cracks or breaks in the silicon-carbide element
  • Short cycling or repeated ignition lockouts
  • Igniter glows weakly or unevenly compared to new

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS101HRCB0AAA — OEM 1171306 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS101HRCB0AAA — OEM 1171306 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS101HRCB0AAA — OEM 1171306 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online