Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS101HRBB0AAAA — Includes Igniter Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS101HRBB0AAAA — Includes Igniter Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part #1171306) is the original ignition component for the ICP/Heil/Tempstar RGS101HRBB0AAAA gas furnace. The igniter glows red-hot when energized by the control board, providing the heat source that lights the main burners on each call for heat. This listing also includes the matching OEM igniter wiring kit (part #1188370) so you can replace cracked or brittle leads at the same time. A failed igniter is the single most common cause of furnace no-heat calls: the silicon nitride or silicon carbide element becomes brittle with age and thermal cycling, eventually cracking and breaking the circuit. Typical failure symptoms include the furnace running its ignition sequence but never lighting, the inducer and igniter cycling repeatedly, or a visible crack in the glow element.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Voltage 120V
Application Gas Furnace Ignition

Compatibility

Engineered as a direct-fit OEM replacement for the ICP/Heil/Tempstar/Comfortmaker RGS101HRBB0AAAA furnace and the broader RGS101 platform that shares this ignition assembly. Always verify your model and serial tag before ordering to confirm fitment.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter before touching any component.
  2. Access — Remove the lower burner-compartment service panel.
  3. Document — Photograph the igniter bracket position and wire routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift the old igniter out by the ceramic base only — never touch the glow element.
  5. Install — Seat the new igniter so the element sits in the burner flame path, secure the screw, and connect the new wiring kit per your photo.
  6. Test — Restore power, call for heat, and confirm the igniter glows and the burners light within the normal ignition window.

Signs You Need a Replacement

  • Furnace runs the ignition sequence but burners never light
  • Igniter shows no glow or a weak, partial glow
  • Visible crack or chip in the ceramic glow element
  • Repeated lockouts after several failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS101HRBB0AAAA — Includes Igniter Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS101HRBB0AAAA — Includes Igniter Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS101HRBB0AAAA — Includes Igniter Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online