This genuine OEM hot surface igniter (part 1171306) fits the ICP / Tempstar / Heil gas furnace model RGS101HFCB0AAA and ships with the matching igniter wiring kit (part 1188370). The igniter is the silicon-carbide or silicon-nitride element that glows red-hot when energized to ignite the burner gas at the start of every heat cycle. Because it is repeatedly heated and cooled, it is one of the most common furnace wear items. Typical failure symptoms include no ignition and no heat, a furnace that clicks and the inducer runs but the burners never light, or an igniter that is visibly cracked or no longer glows. The included wiring kit lets you replace brittle or heat-damaged leads at the same time.

Specifications

Spec Value
Part Numbers 1171306 (igniter), 1188370 (wiring kit)
Type Hot surface igniter
Brand ICP / Tempstar / Heil
Operating Voltage 120V
Includes Igniter + wiring kit

Compatibility

Direct OEM replacement for the ICP/Tempstar/Heil RGS101HFCB0AAA furnace. Always match the OEM part number — hot surface igniters vary by element material and mounting, and the wrong style will not seat correctly in the burner assembly.

Installation Guide

  1. Safety First — Shut off gas and electrical power, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment door.
  3. Document — Photograph the igniter bracket and wire routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift out the old igniter. Handle the new element only by its ceramic base — never touch the hot surface.
  5. Install — Seat the new igniter, secure the screw, and connect the new wiring kit.
  6. Test — Restore gas and power and confirm the igniter glows and the burners light on a heat call.

Signs You Need a Replacement

  • No heat — inducer runs but burners never ignite
  • Igniter does not glow when energized
  • Visible cracks or chips in the ceramic element
  • Intermittent ignition or repeated lockouts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS101HFCB0AAA — with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS101HFCB0AAA — with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS101HFCB0AAA — with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online