Overview

This OEM hot surface igniter (HSI) is the ignition component for the ICP/Tempstar/Heil RGS101HFAB0AAAA gas furnace. The igniter electrically heats to roughly 2,000°F on a call for heat to ignite the gas burner. When it fails, the furnace will run the inducer and open the gas valve but never light — leaving you with no heat. This listing covers OEM ignitor part 1171306 along with the matching 1188370 igniter wiring kit so the fragile element seats and connects correctly without splicing aged leads. Operates on standard 120V furnace ignition voltage.

Specifications

Spec Value
Part Number 1171306 (Ignitor), 1188370 (Wiring Kit)
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil / Comfortmaker)
Voltage 120V
Application Gas furnace ignition
Fitment OEM

Compatibility

Engineered for the ICP family model RGS101HFAB0AAAA and shares the same igniter platform used across many Tempstar, Heil, and Comfortmaker gas furnaces. Confirm your existing igniter terminal and bracket match before installing.

Installation Guide

  1. Safety First — Disconnect furnace power at the switch/breaker and verify zero voltage with a multimeter before opening the cabinet.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter mounting and wire routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and carefully withdraw the fragile element — never touch the element surface with bare fingers.
  5. Install — Mount the new 1171306 igniter, install the 1188370 wiring kit, and reconnect per your photo.
  6. Test — Restore power and watch a full ignition cycle to confirm the element glows and the burner lights.

Signs You Need a Replacement

  • Furnace inducer and gas valve cycle but the burner never ignites (no heat).
  • Visible crack, blistering, or white spotting on the igniter element.
  • Igniter does not glow on a call for heat.
  • Repeated ignition lockout after several failed trial-for-ignition cycles.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS101HFAB0AAAA — OEM 1171306 with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS101HFAB0AAAA — OEM 1171306 with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS101HFAB0AAAA — OEM 1171306 with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.