Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS101HEAA0AAAA — OEM 1171306 with Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS101HEAA0AAAA — OEM 1171306 with Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (HSI) is the direct-fit ignition component for the ICP/Heil/Tempstar RGS101HEAA0AAAA gas furnace. The igniter (OEM part 1171306) is a high-resistance silicon-carbide element that glows red-hot when energized to light the burner gas at each heating call. This listing ships with the matching wiring kit / igniter harness (OEM part 1188370) so the element and its connector are replaced together for a clean, lasting repair. A failed igniter is a leading cause of "no heat" — the inducer and blower may run and the gas valve may open, but without a glowing igniter the burners never light and the control board locks out after repeated failed trials.

Specifications

Spec Value
OEM Part Number 1171306 (igniter)
Included Kit 1188370 (wiring kit / igniter harness)
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar / Comfortmaker
Element Silicon carbide
Application Gas furnace ignition
Fitment OEM exact-fit

Compatibility

Engineered for the ICP RGS101HEAA0AAAA gas furnace and shared-platform Heil, Tempstar, and Comfortmaker models that use the 1171306 igniter and 1188370 harness. Always confirm your model and part number on the unit rating plate before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, shut off the gas, and verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the igniter mounting and harness routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and lift out the old igniter. Handle the new element by its ceramic base only — never touch the silicon-carbide tip.
  5. Install — Mount the new igniter, route and connect the new wiring kit per your photo, and confirm clearance from the burners.
  6. Test — Restore gas and power, call for heat, and verify the igniter glows and the burners light within the trial period.

Signs You Need a Replacement

  • Furnace runs the inducer and blower but burners never light (no heat).
  • Igniter does not glow, or glows weakly/unevenly.
  • Visible cracks, chips, or white/blistered spots on the element.
  • Control board flashing an ignition-failure or lockout code.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS101HEAA0AAAA — OEM 1171306 with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS101HEAA0AAAA — OEM 1171306 with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS101HEAA0AAAA — OEM 1171306 with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online