Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS091LTCB0AAA — OEM Kit with Wiring | Ships Today
ICP

ICP Hot Surface Igniter for RGS091LTCB0AAA — OEM Kit with Wiring | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter kit for the ICP RGS091LTCB0AAA gas furnace includes the igniter element (part number 1171306) and the matching igniter wiring kit (part number 1188370). On each call for heat, the furnace control board powers the igniter; it glows white-hot and lights the main burners. Hot surface igniters are brittle and degrade over thousands of heating cycles — the silicon carbide or nitride element develops hairline cracks and eventually fails open. A bad igniter is the leading cause of no-heat calls: the inducer runs and the gas valve tries to open, but the burners never light, so the furnace locks out. Replacing the igniter together with its wiring harness restores reliable ignition and eliminates intermittent, heat-stressed connections.

Specifications

Spec Value
Part Numbers 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP (Heil / Tempstar)
Fits Model RGS091LTCB0AAA
Includes Igniter element + wiring harness kit
Fitment OEM direct replacement

Compatibility

Built for the ICP / Heil / Tempstar RGS091LTCB0AAA gas furnace and shared-platform models using this hot surface igniter and harness. Confirm the part numbers and connector style against your existing igniter before installing.

Installation Guide

  1. Safety First — Turn off gas and disconnect power. Verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter mounting, bracket position, and wiring before disconnecting.
  4. Remove — Unplug the harness, remove the mounting screw, and withdraw the old igniter without touching the new element with bare fingers.
  5. Install — Mount the new igniter, route and connect the wiring kit, and confirm proper alignment over the burner.
  6. Test — Restore gas and power, then watch a full cycle to verify the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace runs the inducer but burners never light (no heat)
  • Igniter does not glow during the ignition sequence
  • Visible cracks, breaks, or white spots on the element
  • Repeated ignition lockouts or intermittent heating

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS091LTCB0AAA — OEM Kit with Wiring | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS091LTCB0AAA — OEM Kit with Wiring | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS091LTCB0AAA — OEM Kit with Wiring | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online