Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS091LFBA0AAAA — Silicon Carbide w/ Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS091LFBA0AAAA — Silicon Carbide w/ Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

The hot surface igniter lights the burners on your ICP Tempstar/Heil RGS091LFBA0AAAA gas furnace. On a call for heat, the control board energizes this igniter, heating its silicon carbide element until it glows and ignites the gas at the manifold. Igniters are among the most common no-heat failures: the brittle element cracks, develops hairline fractures, or simply burns through after thousands of cycles. This OEM kit pairs igniter part 1171306 with the matching igniter wiring kit 1188370, giving you the correct connector and pigtail for a clean, reliable replacement.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter
Element Silicon Carbide
Brand ICP / Tempstar / Heil
Application Gas Furnace Ignition
Fitment OEM Direct Replacement

Compatibility

Direct OEM replacement for the ICP Tempstar Heil RGS091LFBA0AAAA gas furnace and equivalent 90,000 BTU ICP-family models (Tempstar, Heil, Comfortmaker, Arcoaire) built on the same platform. Confirm against your unit's parts breakdown before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect electrical power. Verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter mounting and wire routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and withdraw the old igniter without touching the element.
  5. Install — Mount the new igniter using the supplied wiring kit; handle by the ceramic base only, never the element. Reconnect per your photo.
  6. Test — Restore gas and power, run a heat cycle, and confirm the igniter glows and lights the burners cleanly.

Signs You Need a Replacement

  • Blower runs but burners never light (no ignition)
  • Visible cracks, breaks, or white spots on the element
  • Igniter glows weakly or not at all during a heat call
  • Furnace locks out after repeated failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS091LFBA0AAAA — Silicon Carbide w/ Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS091LFBA0AAAA — Silicon Carbide w/ Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS091LFBA0AAAA — Silicon Carbide w/ Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online