Overview

This OEM hot surface igniter (part number 1171306) is the direct ignition source for the ICP / Heil / Tempstar RGS091HTAA0AAAA gas furnace. When a heat call is initiated, the control board energizes the igniter, which glows hot enough to ignite the gas at the burners. This kit also includes the matching igniter wiring harness (part number 1188370) so you can replace a cracked or corroded connector at the same time. A failed igniter is one of the most common causes of a no-heat furnace: the element develops hairline cracks from thermal cycling, finally breaks open electrically, and the furnace locks out before it can light. Replacing the igniter restores reliable, on-demand ignition.

Specifications

Spec Value
Part Number 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Fits Model RGS091HTAA0AAAA
Application Gas Furnace Ignition
Fit OEM Replacement

Compatibility

Designed for the ICP / Heil / Tempstar / Comfortmaker RGS091HTAA0AAAA furnace and other models from the same family that call for OEM igniter 1171306 with wiring kit 1188370. Always confirm the part number on your existing igniter before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, and shut off the gas. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the igniter mounting and wiring routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and carefully withdraw the old igniter. Handle the new element by its ceramic base only — skin oils can shorten its life.
  5. Install — Seat the new igniter in the burner bracket, secure the screw, and connect the new wiring kit per your photo.
  6. Test — Restore gas and power, run a heat cycle, and confirm the igniter glows and lights the burners cleanly.

Signs You Need a Replacement

  • Furnace blower runs but burners never light (no heat).
  • Igniter does not glow during a heat call.
  • Visible cracks, breaks, or white-spotted corrosion on the element.
  • Furnace locks out and requires repeated resets before lighting.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS091HTAA0AAAA — Silicon Nitride OEM 1171306 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS091HTAA0AAAA — Silicon Nitride OEM 1171306 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS091HTAA0AAAA — Silicon Nitride OEM 1171306 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.