This OEM hot surface igniter kit for the ICP / Heil / Tempstar RGS091HSCA0AAA gas furnace includes the igniter (part 1171306) and its dedicated wiring harness kit (part 1188370). On each heat call, the control board sends 115V to the igniter, which glows white-hot to ignite the burner gas. Hot surface igniters are one of the most common furnace failure points — the silicon carbide or silicon nitride element is brittle and degrades with every heating cycle until it cracks or stops reaching ignition temperature. Symptoms of a failed igniter include no heat, a furnace that clicks and runs the inducer but never lights, repeated lockouts after several ignition attempts, or a visibly cracked/broken igniter element. The included wiring kit ensures a clean, reliable connection and avoids reusing a brittle, heat-fatigued harness.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter with Wiring Kit
Brand ICP (Heil / Tempstar / Comfortmaker)
Voltage 115 VAC
Fit OEM Direct Replacement

Compatibility

Factory-specified igniter kit for the ICP / Heil / Tempstar RGS091HSCA0AAA and related RGS091-series hot surface ignition furnaces. The included wiring kit adapts the connector for a proper fit. Confirm part numbers 1171306 and 1188370 against your existing components before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker. Verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel to expose the igniter.
  3. Document — Photograph the igniter position and wiring connector before removal.
  4. Remove — Unplug the igniter harness and remove the mounting screw. Handle the old igniter by the ceramic base only — never touch the element.
  5. Install — Mount the new igniter (touching only the ceramic base), then connect the new wiring kit harness.
  6. Test — Restore power, start a heat call, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • No heat — inducer runs but burners never ignite
  • Furnace locks out after several failed ignition attempts
  • Igniter does not glow or glows weakly
  • Visibly cracked, chipped, or broken igniter element

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS091HSCA0AAA — OEM 1171306 with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS091HSCA0AAA — OEM 1171306 with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS091HSCA0AAA — OEM 1171306 with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.