Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS091HRCA0AAA — Furnace Ignition Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS091HRCA0AAA — Furnace Ignition Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part 1171306) with wiring kit (1188370) is the direct-replacement ignition component for the ICP / Tempstar / Heil RGS091HRCA0AAA gas furnace. The hot surface igniter glows red-hot when energized by the control board, igniting the gas at the burners during each heat cycle. Because it is repeatedly heated and cooled, the silicon-carbide or silicon-nitride element becomes brittle over time and is one of the most common furnace failure points. Symptoms of a failed igniter include no ignition, a furnace that clicks but never lights, a cracked or visibly broken element, or short cycling on ignition lockout. This kit includes the matched wiring harness so the connector and pigtail are replaced together for a clean, reliable install.

Specifications

Spec Value
Part Number 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Fit OEM Direct Replacement
Application Gas Furnace Ignition
Includes Igniter + Wiring Harness Kit

Compatibility

Engineered for the ICP, Tempstar, and Heil RGS091HRCA0AAA furnace. The matching part numbers 1171306 and 1188370 confirm correct fitment for this model's burner assembly and control wiring.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and verify zero voltage with a multimeter. Shut off the gas supply.
  2. Access — Remove the furnace front service panel.
  3. Document — Photograph the igniter wiring and connector routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and carefully withdraw the old igniter without touching the element.
  5. Install — Mount the new igniter (handle only by the ceramic base), secure the screw, and connect the new wiring kit per your photo.
  6. Test — Restore gas and power, then run a heat cycle and confirm the igniter glows and lights the burners.

Signs You Need a Replacement

  • Furnace does not ignite or locks out after several tries
  • Igniter element is cracked, broken, or no longer glows
  • Visible white/blistered spots on the element
  • Intermittent ignition or repeated short cycling on startup

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS091HRCA0AAA — Furnace Ignition Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS091HRCA0AAA — Furnace Ignition Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS091HRCA0AAA — Furnace Ignition Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online