Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS091HRBB0AAAA — OEM 1171306 with Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS091HRBB0AAAA — OEM 1171306 with Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part 1171306) is the direct-replacement ignition component for the ICP/Heil/Tempstar RGS091HRBB0AAAA gas furnace, and ships with the matching igniter wiring kit (part 1188370). The hot surface igniter is energized by the furnace control board at the start of each heating cycle; it heats to over 2,000°F to ignite the gas as it leaves the burner manifold. Because it is a brittle silicon-carbide or nitride element that thermal-cycles every call for heat, it is one of the most common furnace failure points. Typical symptoms of a failed igniter are no ignition, a furnace that clicks and the inducer runs but no flame appears, a visible crack or no glow in the element, or repeated lockouts after three failed ignition attempts.

Specifications

Spec Value
Part Number 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar / Comfortmaker
Application Gas Furnace Ignition
Fits Model RGS091HRBB0AAAA
Fitment OEM Direct Replacement

Compatibility

Engineered as the factory ignition component for the ICP RGS091HRBB0AAAA 90,000+ BTU gas furnace and the closely related Heil, Tempstar, and Comfortmaker models built on the same platform. The included wiring kit ensures a clean plug connection when the original harness has been heat-damaged.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and gas at the shutoff. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner/service panel.
  3. Document — Photo the igniter mounting and wire routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift out the old igniter without touching the element.
  5. Install — Mount the new igniter handling it only by the ceramic base, install the wiring kit, and reconnect per your photo.
  6. Test — Restore gas and power, then watch a full ignition cycle to confirm glow, flame, and steady operation.

Signs You Need a Replacement

  • Furnace inducer runs but burners never light
  • Igniter shows no glow or a visible crack
  • System locks out after three ignition attempts
  • Intermittent or delayed heating that worsens over time

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS091HRBB0AAAA — OEM 1171306 with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS091HRBB0AAAA — OEM 1171306 with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS091HRBB0AAAA — OEM 1171306 with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online