Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS091HFCA0AAA — OEM 1171306 with Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS091HFCA0AAA — OEM 1171306 with Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM hot surface igniter (Part No. 1171306), supplied with its matching igniter wiring kit (Part No. 1188370), is built for the ICP / Tempstar / Heil RGS091HFCA0AAA gas furnace. The hot surface igniter glows red-hot when the furnace control board energizes it, igniting the gas at the burners on each heat call. Over thousands of cycles the silicon nitride or carbide element becomes brittle and eventually cracks, leaving the furnace unable to light. The included wiring kit ensures a clean, properly terminated connection so you replace both the fragile igniter and its often-degraded harness in one job.

Specifications

Spec Value
Part Number 1171306 (Igniter)
Included Kit 1188370 (Wiring Kit, Igniter)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Function Burner Ignition
Fits Model RGS091HFCA0AAA

Compatibility

Designed for the ICP Tempstar Heil RGS091HFCA0AAA furnace and matched ICP-family gas furnaces using this igniter and harness combination. Confirm the connector and mounting bracket against your existing igniter before installation.

Installation Guide

  1. Safety First — Shut off gas and disconnect power to the furnace, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the igniter position and the wiring harness routing before disconnecting.
  4. Remove — Unplug the igniter connector and remove the mounting screw; handle the old igniter by its ceramic base only.
  5. Install — Mount the new igniter without touching the glow element, then connect using the supplied wiring kit per your photo.
  6. Test — Restore gas and power, start a heat call, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace clicks and tries to start but burners never light
  • Visible crack or broken element on the igniter
  • No glow during the ignition sequence
  • Repeated lockouts after several failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS091HFCA0AAA — OEM 1171306 with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS091HFCA0AAA — OEM 1171306 with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS091HFCA0AAA — OEM 1171306 with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online