Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS091HFAB0AAAA — OEM 1171306 with Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS091HFAB0AAAA — OEM 1171306 with Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part number 1171306) is the factory ignition component for the ICP/Tempstar/Heil RGS091HFAB0AAAA gas furnace, and this listing includes the matching igniter wiring kit (1188370). When the furnace calls for heat, the igniter energizes at 120V and glows red-hot to light the burner gas. Hot surface igniters are among the most frequently replaced furnace parts because the brittle silicon-carbide/silicon-nitride element fractures over repeated heating and cooling cycles. Typical symptoms of a failed igniter include no ignition, the furnace attempting to light but never firing, the blower pushing cold air, lockout on ignition failure, or visible cracks and white hot-spots on the element. Replacing the wiring kit alongside the igniter renews heat-damaged leads and connectors at the same time.

Specifications

Spec Value
Part Number 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Voltage 120V
Application Gas Furnace Ignition
Fit OEM Direct Replacement

Compatibility

Engineered as a direct OEM fit for the ICP/Tempstar/Heil RGS091HFAB0AAAA gas furnace. Confirm your model and serial tag, and verify the existing igniter part number when possible, before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, verify zero voltage with a multimeter, and shut off the gas supply.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter mounting and wiring connector before disconnecting.
  4. Remove — Unplug the harness, remove the mounting screw(s), and withdraw the old igniter without touching the element.
  5. Install — Mount the new igniter in the same orientation, install the new wiring kit, and reconnect per your photo. Handle the element by the ceramic base only.
  6. Test — Restore gas and power and watch a full ignition cycle to confirm the igniter glows and the burner lights.

Signs You Need a Replacement

  • Furnace fails to ignite or locks out on ignition failure.
  • Igniter does not glow or glows weakly/unevenly.
  • Visible cracks, white spots, or pitting on the element.
  • Intermittent no-heat calls, especially on cold mornings.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS091HFAB0AAAA — OEM 1171306 with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS091HFAB0AAAA — OEM 1171306 with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS091HFAB0AAAA — OEM 1171306 with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online