Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS091HDBA0AAAA – OEM 1171306 w/ Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS091HDBA0AAAA – OEM 1171306 w/ Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part 1171306), paired with its matching igniter wiring kit (part 1188370), is the ignition component that lights the burners in the ICP / Heil / Tempstar RGS091HDBA0AAAA gas furnace. When the control board calls for heat, line voltage heats the igniter element until it glows hot enough to ignite the gas. Hot surface igniters are brittle and degrade with every heating cycle — the most common failure is a cracked or burned-out element that prevents the furnace from lighting, leaving you with a system that blows cold air or locks out on ignition failure. Replacing it with the correct OEM igniter and wiring harness restores fast, reliable ignition.

Specifications

Spec Value
Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter
Brand ICP (Heil / Tempstar / Comfortmaker)
Voltage 120V
Application Gas Furnace Ignition
Compatible Model RGS091HDBA0AAAA

Compatibility

Direct OEM replacement for the ICP / Heil / Tempstar RGS091HDBA0AAAA gas furnace. The included wiring kit ensures a clean, correct connection to the furnace harness. Confirm your part number before ordering.

Installation Guide

  1. Safety First – Turn off gas and disconnect electrical power to the furnace. Verify zero voltage with a multimeter.
  2. Access – Remove the furnace burner compartment panel to expose the igniter near the burners.
  3. Document – Photograph the igniter position and wiring before removal.
  4. Remove – Unplug the igniter connector and remove the mounting screw, handling the old igniter by its ceramic base only.
  5. Install – Mount the new igniter without touching the element, then connect the new wiring kit per your photo.
  6. Test – Restore gas and power, initiate a heat call, and verify the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace blows cold air or fails to ignite
  • System locks out on ignition failure after several attempts
  • Visible cracks or breaks in the igniter element
  • Igniter does not glow during a heat call

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS091HDBA0AAAA – OEM 1171306 w/ Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS091HDBA0AAAA – OEM 1171306 w/ Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS091HDBA0AAAA – OEM 1171306 w/ Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online