Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS090SECB0AAA — 120V Furnace Ignitor with Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS090SECB0AAA — 120V Furnace Ignitor with Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (HSI) is the ignition component for the ICP/Heil/Tempstar RGS090SECB0AAA gas furnace. When the furnace calls for heat, the control board energizes this 120V igniter, which glows white-hot and lights the burner gas. Over time, the silicon-carbide or silicon-nitride element develops micro-cracks from repeated thermal cycling and becomes brittle, leading to no-heat calls, delayed ignition, or repeated lockouts. This kit includes the igniter (OEM 1171306) and the matching igniter wiring kit (OEM 1188370) so you have the correct harness and connector for a clean, reliable replacement.

Specifications

Spec Value
Part Number 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Voltage 120V
Application Gas furnace ignition
Fits Model RGS090SECB0AAA

Compatibility

Engineered for the ICP/Heil/Tempstar RGS090SECB0AAA 90,000 BTU gas furnace and related RGS-series models that use the same ignition system. Always confirm your furnace part number against the unit rating plate before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect power at the furnace switch and breaker. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner/service panel.
  3. Document — Photograph the igniter mounting and the wiring harness routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and lift the old igniter out. Handle by the ceramic base only — never touch the element.
  5. Install — Mount the new igniter, install the included wiring kit, and reconnect per your photo. Keep the element clear of the burner.
  6. Test — Restore gas and power, then run a heat cycle and confirm the igniter glows and the burner lights promptly.

Signs You Need a Replacement

  • Furnace blower runs but there is no flame or heat.
  • Visible cracks, chips, or breaks in the igniter element.
  • Delayed ignition, repeated retries, or hard lockouts.
  • No glow on the igniter during a heat call.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS090SECB0AAA — 120V Furnace Ignitor with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS090SECB0AAA — 120V Furnace Ignitor with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS090SECB0AAA — 120V Furnace Ignitor with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.