Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS090SECA0AAA — Silicon Nitride with Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS090SECA0AAA — Silicon Nitride with Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter assembly (ignitor part #1171306) is the direct ignition source for the ICP/Heil/Tempstar RGS090SECA0AAA gas furnace. When the thermostat calls for heat and the gas valve opens, the control board energizes this igniter, which heats to over 2,000°F to ignite the burner gas. This listing includes the matching igniter wiring kit (#1188370) so you have the correct harness and ceramic plug for a clean, reliable connection. A failed or cracked igniter is one of the most common causes of furnace no-heat calls — the unit will run the inducer and call for ignition but never light, or it will lock out after several failed trials.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Fits Model RGS090SECA0AAA
Voltage 120V (line voltage)
Application Gas furnace burner ignition

Compatibility

Engineered as a factory replacement for the ICP/Heil/Tempstar RGS090SECA0AAA furnace. The included wiring kit ensures the harness connector matches this model's control board pinout. Always verify your existing igniter part number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter. Shut off the gas supply.
  2. Access — Remove the furnace blower/burner access panel.
  3. Document — Photograph the igniter mounting and wire routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift the old igniter free. Handle only by the ceramic base — never touch the silicon nitride element.
  5. Install — Mount the new igniter, install the wiring kit harness, and reconnect per your photo. Confirm the element sits correctly over the burner.
  6. Test — Restore gas and power, run a heat cycle, and confirm the igniter glows and the burner lights within the trial-for-ignition window.

Signs You Need a Replacement

  • Furnace inducer runs but burner never lights (no-heat)
  • Visible cracks, blisters, or breaks in the igniter element
  • Control board locks out after repeated failed ignition attempts
  • Igniter glows weakly or not at all during the call for heat

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS090SECA0AAA — Silicon Nitride with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS090SECA0AAA — Silicon Nitride with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS090SECA0AAA — Silicon Nitride with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online