Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS090SEBA0AGAA — Includes Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS090SEBA0AGAA — Includes Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (HSI) is the ignition component for the ICP / Tempstar / Heil RGS090SEBA0AGAA gas furnace. On a call for heat, the furnace control board energizes the igniter, which glows red-hot to light the burners as the gas valve opens. A cracked, eroded, or open igniter is one of the most common causes of furnace no-heat lockouts. This listing includes OEM igniter 1171306 and OEM igniter wiring kit 1188370, so you have the connector and harness needed for a clean replacement. Hot surface igniters are brittle and wear out over thousands of heating cycles — symptoms of failure include no ignition, repeated lockouts after a few ignition attempts, or an igniter that fails to glow.

Specifications

Spec Value
Part Number 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter (HSI)
Brand ICP / Tempstar / Heil
Application Gas furnace burner ignition
Includes Igniter + igniter wiring kit
Fitment OEM direct replacement

Compatibility

Engineered as a direct-fit OEM replacement for the ICP / Tempstar / Heil RGS090SEBA0AGAA gas furnace. ICP-built equipment is sold under multiple labels (Tempstar, Heil, Comfortmaker, Day & Night, Arcoaire), so this igniter may also fit equivalent 90,000 BTU RGS-series models. Verify your existing igniter part number before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect electrical power to the furnace; verify zero voltage with a multimeter.
  2. Access — Remove the furnace blower/burner access panel.
  3. Document — Photograph the igniter mounting and wiring before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and carefully lift out the old igniter — never touch the silicon carbide element with bare fingers.
  5. Install — Mount the new igniter, install the included wiring kit, and reconnect per your photo.
  6. Test — Restore gas and power, start a heat cycle, and confirm the igniter glows and burners light.

Signs You Need a Replacement

  • Furnace runs through ignition attempts then locks out with no heat
  • Igniter does not glow when commanded
  • Visible cracks, chips, or white/eroded spots on the element
  • Open circuit / no continuity when tested with a meter

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS090SEBA0AGAA — Includes Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS090SEBA0AGAA — Includes Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS090SEBA0AGAA — Includes Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online