Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS090SEAB0AGAA — Includes Igniter Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS090SEAB0AGAA — Includes Igniter Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the OEM hot surface igniter for the ICP / Heil / Tempstar RGS090SEAB0AGAA gas furnace, supplied with the matching igniter wiring kit (OEM 1171306 igniter and 1188370 wiring kit igniter). The hot surface igniter is the component that glows red-hot on a call for heat and lights the burner gas. Because it operates at extreme temperatures on every heating cycle, it is one of the most common furnace failure points. Symptoms of a failed igniter include a furnace that will not light, a blower that runs without heat, repeated ignition lockouts, or a visible crack in the silicon-carbide or silicon-nitride element. Installing a genuine OEM igniter with the correct wiring harness ensures proper resistance, plug fitment, and reliable ignition.

Specifications

Spec Value
Part Number 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Voltage 120V
Application Gas Furnace Ignition
Fit OEM Direct Replacement

Compatibility

Engineered as a direct-fit replacement for the ICP/Heil/Tempstar RGS090SEAB0AGAA furnace and shared platform models that use the same ignition assembly. Always confirm against your unit's parts list before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner/service panel.
  3. Document — Photograph the igniter mounting and wiring before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift out the old igniter without touching the element.
  5. Install — Mount the new igniter, route and connect the supplied wiring kit, handling the element by its ceramic base only.
  6. Test — Restore power and run a heat cycle to confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • Furnace blower runs but produces no heat
  • Igniter does not glow on a call for heat
  • Repeated ignition lockouts or short cycling
  • Visible cracks or white spots on the igniter element

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS090SEAB0AGAA — Includes Igniter Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS090SEAB0AGAA — Includes Igniter Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS090SEAB0AGAA — Includes Igniter Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online