The ICP igniter electrode (OEM part 1179966) is the ignition component that initiates the burner flame in your ICP, Heil, and Tempstar RGS303HTAA0AAAA gas furnace. On every call for heat the control board energizes this electrode to ignite the gas at the burner. When the electrode cracks, carbons over, or loses its glow, the furnace will lock out after several failed ignition attempts and the system will stop producing heat. Common failure symptoms include no ignition, repeated lockouts, delayed ignition with a small "poof," or an error code on the control board indicating ignition failure. This is a genuine OEM electrode built to the exact resistance and positioning specifications of the original.

Specifications

Spec Value
Part Number 1179966
Description Ignitor Electrode
Type Hot Surface / Electrode
Brand ICP (Heil / Tempstar)
Application Gas Furnace Burner Ignition
Fitment OEM Direct Replacement

Compatibility

This igniter electrode is a direct OEM fit for the ICP/Heil/Tempstar RGS303HTAA0AAAA gas furnace. It is also used across many ICP-family RGS-series furnaces that share the same burner assembly. Always confirm your model and serial number against the part before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then shut off the gas supply. Verify zero voltage with a multimeter before touching any component.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the igniter mounting and wire routing before disconnecting.
  4. Remove — Disconnect the igniter lead, remove the mounting screw(s), and carefully withdraw the old electrode from the burner. Handle by the bracket only — never touch the igniter element.
  5. Install — Mount the new electrode in the same position and gap, reconnect the lead per your photo, and secure the bracket.
  6. Test — Restore gas and power, then run a heat cycle and confirm clean, immediate ignition.

Signs You Need a Replacement

  • Furnace ignites intermittently or not at all
  • Repeated ignition lockouts or ignition-failure error codes
  • Delayed ignition with a noticeable "poof" of gas
  • Visible cracks, carbon buildup, or a weak/no glow on the element

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS303HTAA0AAAA — OEM 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS303HTAA0AAAA — OEM 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS303HTAA0AAAA — OEM 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.