Overview

This is the genuine OEM igniter electrode (part number 1179966) for the ICP / Tempstar / Heil RGS303HSEA0AAAA gas furnace. The igniter electrode is the heart of the ignition system: it creates the high-voltage spark or hot ignition point that lights the main burners on each call for heat. Positioned at the burner assembly, it works with the control board and flame-sensing circuit to start and confirm combustion. When this component cracks, erodes, or carbons over, the furnace will fail to light, short-cycle, or lock out on ignition failure — leaving the home without heat. Replacing a worn igniter electrode is one of the most common heating repairs and restores reliable, on-demand ignition.

Specifications

Spec Value
Part Number 1179966
Description Igniter Electrode
Type Direct Spark / Ignition Electrode
Brand ICP (Tempstar / Heil / Comfortmaker)
Fitment OEM Direct Replacement
Application Gas Furnace Burner Ignition

Compatibility

Engineered as a direct OEM fit for the ICP / Tempstar / Heil RGS303HSEA0AAAA gas furnace. ICP-family equipment (Heil, Tempstar, Comfortmaker, Arcoaire, KeepRite) shares many burner and ignition components, so always confirm against your unit's part number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then shut off the gas supply. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace front service panels to expose the burner assembly.
  3. Document — Photograph the igniter position, gap, and any wiring before disconnecting.
  4. Remove — Unplug the igniter lead and remove the mounting screw(s) securing the electrode bracket. Withdraw the old electrode without touching the ceramic insulator.
  5. Install — Mount the new electrode in the same position, restore the factory spark gap, and reconnect the lead per your photo.
  6. Test — Restore gas and power, then run a heat cycle and confirm the burners light promptly and stay lit.

Signs You Need a Replacement

  • Furnace fails to light or locks out on ignition failure
  • Repeated clicking or sparking with no flame
  • Visible cracks in the ceramic insulator or carbon buildup on the electrode tip
  • Intermittent no-heat calls and short-cycling

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS303HSEA0AAAA — OEM 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS303HSEA0AAAA — OEM 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS303HSEA0AAAA — OEM 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.