This OEM hot surface igniter (part #1179966, IGNITOR ELECTRODE) is the direct-fit ignition component for the ICP/Tempstar/Heil RGS303HRAA0AAAA gas furnace. The igniter receives 120V from the control board on each call for heat, glowing white-hot to ignite the gas at the burners. As a silicon-nitride style hot surface igniter, it is more durable and resistant to thermal shock than older silicon-carbide elements. When this part fails, the furnace will not light — the most common no-heat complaint on this platform. A cracked or burned-out igniter is the #1 wear item in modern gas furnaces and should be handled only by the ceramic base, never the fragile element.

Specifications

Spec Value
Part Number 1179966
Type Hot Surface Igniter Electrode
Brand ICP (Tempstar / Heil)
Voltage 120V
Element Silicon Nitride
Fit OEM Direct Replacement

Compatibility

Engineered for the ICP/Tempstar/Heil RGS303HRAA0AAAA furnace and shared-platform models across the ICP family (Comfortmaker, Arcoaire, KeepRite). Always confirm your existing OEM part number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch/breaker and shut off the gas. Verify zero voltage with a multimeter.
  2. Access — Remove the lower service/blower panel.
  3. Document — Photograph the igniter bracket and wiring before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and lift the old element out — handle only by the ceramic base.
  5. Install — Seat the new igniter, secure the screw, and reconnect the plug per your photo without touching the element.
  6. Test — Restore gas and power, then run a heat cycle and confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • Furnace blower runs but burners never ignite (no heat).
  • Visible crack, blister, or white burn spot on the igniter element.
  • Igniter does not glow during the ignition sequence.
  • Open circuit / infinite resistance when ohm-tested.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS303HRAA0AAAA — Silicon Nitride | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS303HRAA0AAAA — Silicon Nitride | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS303HRAA0AAAA — Silicon Nitride | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.