Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter Electrode for RGS303HDEA0AAAA — OEM | Ships Today
ICP

ICP Hot Surface Igniter Electrode for RGS303HDEA0AAAA — OEM | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM ignitor electrode (part 1179966) is the factory ignition component for ICP / Heil / Tempstar model RGS303HDEA0AAAA. The electrode is responsible for lighting the main burners on each heating cycle. On a call for heat, the control board powers the igniter to produce the spark or hot surface that ignites the gas. A cracked element, eroded tip, or hairline fracture in the electrode prevents light-off, leading to no heat, repeated ignition lockouts, or a furnace that cycles on the limit. Replacing with the exact OEM electrode restores fast, dependable burner ignition.

Specifications

Spec Value
Part Number 1179966
Type Ignitor Electrode
Function Burner ignition
Brand ICP (Heil / Tempstar)
Fit OEM

Compatibility

Designed for ICP / Heil / Tempstar model RGS303HDEA0AAAA and platform-shared furnaces using this ignition electrode. Confirm the mounting bracket and lead connector match your existing igniter before installing.

Installation Guide

  1. Safety First — Shut off gas and disconnect power; verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position, gap, and wiring before removal.
  4. Remove — Disconnect the igniter lead and unscrew the electrode from the burner assembly; handle the element only by its base.
  5. Install — Mount the new OEM electrode without touching the element, set the proper gap, and reconnect the lead.
  6. Test — Restore gas and power and confirm clean burner ignition on a call for heat.

Signs You Need a Replacement

  • No heat — burners won't light on a call
  • Repeated ignition lockouts or short cycling
  • Visible crack, erosion, or carbon buildup on the element
  • Delayed ignition with a small "poof" at light-off

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS303HDEA0AAAA — OEM | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS303HDEA0AAAA — OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS303HDEA0AAAA — OEM | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online